Distributionally Robust Selective Prediction for Reliable EEG-Based Cognitive Fatigue Monitoring Under Distribution Shift.

Abstract

Reliable electroencephalography (EEG)-based cognitive state monitoring is challenged by inter-subject variability, heterogeneous experimental conditions, and distributional shifts. This study presents a distributionally robust risk–coverage optimization approach that maximizes prediction coverage while constraining worst-case selective risk under distributional uncertainty. The approach integrates adaptive abstention with confounder-aware evaluation to distinguish EEG-derived predictive information from temporal and experimental associations. Subject-independent evaluation on CogBeacon yielded an AUROC of 0.678 using EEG alone and 0.816 when combined with contextual features for cumulative fatigue self-report prediction. Total variation-based robust selection reduced accepted-sample prediction error from 14.8% to 12.1%, with coverage decreasing from 48.9% to 38.5%. Analysis of FatigueSet revealed substantial inter-subject variability, with an average increase of 18.02 points in subjective mental fatigue without consistent deterioration in cognitive task performance. These findings highlight the limitations of unconditional EEG-based classification and demonstrate the importance of accounting for distributional uncertainty, predictive reliability, and cognitive state heterogeneity in developing reliable cognitive monitoring systems.